Running the Diagnostics Program

5-15

Table 5-5Actions for Open Errors (continued)

Error Code

Explanation

Action

 

 

 

47

Ring Poll, Ring Beaconing: The PC Card has either

1 and 2b

 

detected a monitor contention (claim token) failure

 

 

or received a beacon MAC frame from the ring.

 

 

 

 

4A

Ring Poll, Remove Received: The PC Card has

2a and 4

 

received a remove ring station MAC frame,

 

 

indicating that a network management function has

 

 

directed this PC Card to get off the ring.

 

 

 

 

55

Request Parameters, Time Out: The insertion timer

1 and 2a

 

expired before this function was completed,

 

 

indicating that the ring can be congested,

 

 

experiencing a high bit-error rate, or losing an

 

 

abnormally high number of tokens or frames. This

 

 

prevents successful transmission of the request

 

 

parameter MAC frame or reception of either the set

 

 

parameter 1 or set parameter 2 MAC frame

 

 

(required response to the PC Card’s request).

 

 

 

 

56

Request Parameters, Ring Failure: The PC Card,

1 and 2a

 

acting as an active monitor, was unable to complete

 

 

the ring purge function successfully. This indicates

 

 

that an error condition has occurred since the

 

 

successful completion of monitor contention (when

 

 

this PC Card became the active monitor).

 

 

 

 

57

Request Parameters, Ring Beaconing: The PC Card

1 and 2b

 

has received a beacon MAC frame from the ring.

 

 

 

 

59

Request Parameters, Parameter Request - Retry

1 and 2a

 

Count Exceeded: The PC Card has detected that the

 

 

ring parameter server is present on the ring but that

 

 

the required response (set parameter 1 or set

 

 

parameter 2 MAC frame) was not received in the

 

 

allotted time. This indicates that the ring can be

 

 

congested, experiencing a high bit-error rate, or

 

 

losing an abnormally high number of tokens or

 

 

frames.

 

 

 

 

5A

Request Parameters, Remove Received: The PC Card

2a and 4

 

has received a remove ring station MAC frame,

 

indicating that a network management function has directed this PC Card to get off the ring.

Page 62
Image 62
3Com 3C389 manual Running the Diagnostics Program