Configuring Channelized Data
Threshold Value-ES
Range: | 1 to 255 |
|
|
Default: | 10 |
|
|
Description: | Specifies the number of errors that must occur within a fixed |
| 15- minute window before an alarm is declared. This is based on |
| the threshold value for Error Seconds, which have: |
| • one or more path code violations |
| • one or more |
| • one or more controlled slip events |
| • a detected alarm indication signal defect |
| For D4 and |
| triggers an errored second. |
|
|
Threshold | |
|
|
Range: | 1 to 255 |
|
|
Default: | 10 |
|
|
Description: | Specifies the number of errors that must occur within a fixed |
| 15- minute window before an alarm is declared. This is based on |
| the threshold value for Bursty Errored Seconds, which have: |
| • fewer than 320 and more than 1 path coding violation error |
| events |
| • no severely errored frame defects |
| • no detected incoming alarm indication signal defects |
| Controlled slips are not included; BES is not incremented during |
| an unavailable second. |
|
|
Channelized Data |