3Com S26x, S27x, S24x How to, Booting Virtual, Enabling/ Disabling, Virtual Ports, Port Speed

Models: S24x S26x S27x

1 156
Download 156 pages 45.33 Kb
Page 130
Image 130

Configuring Channelized Data

Configuring Virtual Ports on the PathBuilder S24x, 26x, and 27x Switch

Introduction

You have to configure a virtual port for each connection between the remote nodes

 

and the PathBuilder S24x, 26x, and 27x switch.

 

How to...

 

 

 

Follow these steps to configure virtual ports between the remote nodes and the

 

PathBuilder S24x, 26x, and 27x switch.

 

 

 

 

 

 

 

Step

 

Action

Result

 

 

 

 

 

 

1

 

From the CTP Main menu, select

The Ports menu appears, as shown

 

 

 

Configure -> Ports.

in Figure 5-3 on page 5-19.

 

 

 

 

 

 

2

 

Enter the Port Number. This value

The Port Type: parameter appears.

 

 

 

should be 100 or above to configure a

 

 

 

 

virtual port.

 

 

 

 

 

 

 

3

 

Enter X25 for an X.25 connection or

The standard port parameters for

 

 

 

FR for a Frame Relay connection.

X.25 or Frame Relay appear in

 

 

 

 

sequence. Refer to the appropriate

 

 

 

 

manuals for details.

 

 

 

 

 

 

4

 

Fill in the remaining parameters, and

This saves the record in CMEM.

 

 

 

enter a semicolon <;>. Press Return

 

 

 

 

when you are finished.

 

 

 

 

 

 

 

5

 

Perform a Node boot.

This implements the configuration

 

 

 

 

changes you made.

Booting Virtual

 

 

 

 

 

 

 

Boot a virtual port by entering the virtual port number and issuing a port boot

Ports

command. Booting a virtual port brings down SVCs associated with that virtual port,

 

but does not affect the operation of the T1 or E1 port, or of any other virtual ports.

Enabling/ Disabling

 

 

 

Enabling or disabling a virtual port has no effect on a T1 or E1 port or other virtual

Virtual Ports

ports. However, disabling a T1 or E1 port makes all associated virtual ports unusable.

 

Enabling a T1 or E1 port makes all associated virtual ports usable; their SVCs can be

 

established. Virtual ports previously disabled via the disable port command remain

 

disabled.

 

 

Port Speed

 

 

 

Port speed for virtual ports is set from the DS0 Rate parameter in the Virtual Ports

 

Mapping Table. You can set the rate of speed for traffic at 56k or 64k. See the

 

“Configuring Virtual Port Mapping Table” section on page 5-20for more details.

5-18

Channelized Data

Page 130
Image 130
3Com S26x, S27x, S24x installation manual How to, Booting Virtual, Enabling/ Disabling, Virtual Ports, Port Speed