Numeric | Status | Service | Description/Comments |
Display (continued) | LED | LED |
|
|
|
|
|
48 | OFF | ON | FLASH write failure |
|
|
|
|
49 | OFF | ON | Read error on Port 6 |
|
|
|
|
60 | OFF | ON | Local DRAM exhausted |
|
|
|
|
8.8. | ON | OFF | PBIST (~3 seconds) |
|
|
|
|
(Blank) | OFF | OFF | PBIST |
|
|
|
|
L0 | OFF | OFF | Load Phase |
|
|
| IPL image, (~ 1 second) |
|
|
|
|
L1 | OFF | OFF | Load Phase |
|
|
| loads the FBIST image (~ 1 second) |
|
|
|
|
(Rotating segments) | ON | OFF | FBIST lamp test (~ 2 seconds) |
|
|
|
|
L2 | OFF | OFF | Load Phase |
|
|
| loads the ONS image (several seconds) |
|
|
|
|
L3 | OFF | OFF | Load Phase |
|
|
| modules in ONS image (~ 3 seconds) |
|
|
|
|
L4 | OFF | OFF | Load Phase |
|
|
| and all ONS modules (~10 seconds) |
|
|
|
|
CR | OFF | ON | PathBuilder S24x, 26x, and 27x switch has |
|
|
| crashed |
|
|
|
|
(Blank with flashing | OFF | OFF | Normal system operation |
dashes) |
|
|
|
|
|
|
|
Note
During a warm start, display sequencing starts with the “L2” code.
PathBuilder S24x, 26x, and 27x Switch Error Codes |