Power-Up Diagnostics/Verification

Power-Up Diagnostics/Verification

Introduction

Diagnostics run when a node is powered up. Basic tests are run from PROM and

 

more extensive diagnostics are run during startup.

 

If the node detects a lack of software, it sends a message to the CTP. The yellow LED

 

lights and a 2-digit code is displayed. You must initiate a software coldload if

 

needed.

Power Up

 

This is the power-up sequence.

Sequence

Function

Description

 

 

ROM-based diagnostics

Local core self-tests. Boots PROM

 

checksum, MPU test, Program RAM test.

 

 

FLASH verification

Checksum FLASH image.

 

 

Loads RAM diagnostics

Uncompresses FLASH diagnostics image

 

to RAM and executes.

 

 

RAM-based diagnostics

Tests I/O cards and everything else on card.

 

 

Loads RAM operational

Uncompresses FLASH operational

software

software image to RAM and executes.

 

 

Verifies Config database

Verifies resident CMEM database.

 

 

Node Restarts The three types of restarts are:

Coldstart

Warmstart

Default Node

Node Coldstart A node coldstart is similar to a power-up. It follows the power-up sequence except that it is initiated when the operator presses the RESET button on the front panel or when certain software faults occur. All calls are cleared along with Event queues. A Node coldstart loads only configuration memory.

Node Warmstart A node warmstart can be initiated by a software fault or an operator command. It is identical to a coldstart except for the following:

No diagnostic testing is performed.

Code downloads are not performed unless necessary.

Event logs are not erased.

3-24

PathBuilder S24x, 26x, and 27x Switch Hardware Installation

Page 92
Image 92