Power-Up Diagnostics/Verification
Introduction | Diagnostics run when a node is powered up. Basic tests are run from PROM and |
| more extensive diagnostics are run during startup. |
| If the node detects a lack of software, it sends a message to the CTP. The yellow LED |
| lights and a |
| needed. |
Power Up |
|
This is the |
Sequence
Function | Description |
|
|
Local core | |
| checksum, MPU test, Program RAM test. |
|
|
FLASH verification | Checksum FLASH image. |
|
|
Loads RAM diagnostics | Uncompresses FLASH diagnostics image |
| to RAM and executes. |
|
|
Tests I/O cards and everything else on card. | |
|
|
Loads RAM operational | Uncompresses FLASH operational |
software | software image to RAM and executes. |
|
|
Verifies Config database | Verifies resident CMEM database. |
|
|
Node Restarts The three types of restarts are:
•Coldstart
•Warmstart
•Default Node
Node Coldstart A node coldstart is similar to a
Node Warmstart A node warmstart can be initiated by a software fault or an operator command. It is identical to a coldstart except for the following:
•No diagnostic testing is performed.
•Code downloads are not performed unless necessary.
•Event logs are not erased.
PathBuilder S24x, 26x, and 27x Switch Hardware Installation |