Ethernet Cable Pinouts

Ethernet Cable Pinouts

Introduction

This cable may have a maximum length of up to 100m and must conform to the

 

802.3 10BaseT specification, with a nominal impedance of 100 ohms. Category 3, 4,

 

or 5 cable may be used. Category 4 or 5 is preferred.

Additional

Information

Ethernet RJ-45S Connector Signals

Refer to ANSI/TIA/EIA 568A and the following references:

CSMA/CD Access Method and Physical Layer Specifications, IEEE standard 802.3-1992.

Draft supplement to IEEE standard 802.3, System Considerations for Multi Segment 10B/S Baseband Networks (Chapter 13) and Medium Attachment Unit and Baseband Medium Specification, Type 10BaseT (Chapter 14), p802.3i-1990.

The following table shows the Ethernet RJ-45S connector signals.

Pin

Signal

 

 

1

Transmit +

 

 

2

Transmit -

 

 

3

Receive +

 

 

6

Receive -

 

 

Ethernet DB-15The AIU cable uses male DB-15 to female DB-15 connectors with slide latches in a Connector Signals straight-through connection.

The twisted pair combinations are 1/2, 3/6, and 4/5, and may be used for Ethernet.

This cable may have a maximum length of up to 50m and must conform to the 802.3 10BASE5 specification.

The following table shows the Ethernet DB-15 connector signals.

Pin

Signal

 

 

1

Shield

 

 

2

Collision+

 

 

3

Transmit+

 

 

4

Shield

 

 

5

Receive+

 

 

6

Ground

 

 

8

Shield

 

 

9

Collision-

 

 

10

Transmit-

 

 

11

Shield

 

 

A-6

Cables

Page 140
Image 140