Hardware Components

Enclosure

Introduction

 

This section provides detailed information about the parts of the PathBuilder S24x,

 

26x, and 27x switch enclosure.

Front Panel

 

The PathBuilder S24x, 26x, and 27x switch front panel (see Figure 1-6) has:

 

• Three status LEDs

 

• A 2-character numeric LED display

 

• A RESET switch

Status LEDs

 

The three status LEDs are:

 

• Power (green) — When on, indicates that power is on and all DC voltages are

 

within specifications.

 

• Status (green) — When on, indicates that the PathBuilder S24x, 26x, and 27x

 

switch node is executing either a power-up diagnostic or a software download.

 

This LED is normally off.

 

• Service (yellow) — When on, indicates a hardware failure. This LED is

 

normally off.

Numeric LED

 

The 2-character numeric LED display provides system diagnostic codes. When the

Display

Service LED is on, a 2-digit code on the numeric LED display corresponds to a

 

certain event.

Reset Switch

 

The RESET switch resets the node. Pressing the RESET switch is the equivalent of a

 

power-up operation which clears all existing calls and brings down all links.

Power Supply

 

The power supply is mounted at the top rear of the chassis. The AC switchable power

 

supply can operate at a nominal 110 or a nominal 230 Volts. For information about

 

maintaining and replacing the power supply, refer to Chapter 4, Maintenance.

Note

For this unit, the -48VDC Power Option is also available.

About the PathBuilder S24x, 26x, and 27x switch