Configuring Channelized Data

Threshold Value LES

Range:

1 to 255

 

 

Default:

10

 

 

Description:

Specifies the number of errors that must occur within a fixed

 

15- minute window before an alarm is declared. This is based on

 

the threshold value for Line Error Seconds, which are seconds in

 

which one or more line code violation error events are detected.

 

 

Threshold Value-LCV

 

 

Range:

1 to 255

 

 

Default:

10

 

 

Description:

Specifies the number of errors that must occur within a fixed

 

15- minute window before an alarm is declared. This is based on

 

the threshold value for Line Code Violations, which are the

 

occurrences of either a bipolar violation or excessive zeroes error

 

events.

 

 

Threshold Value-PCV

 

 

Range:

1 to 255

 

 

Default:

10

 

 

Description:

Specifies the number of errors that must occur within a fixed

 

15- minute window before an alarm is declared. This is based on

 

the threshold value for Path Coding Violations, which are frame

 

synchronization bit errors in the D4 and E1-noCRC formats, or

 

CRC errors in the ESF and E1-CRC formats.

 

 

Threshold Value-CSS

 

 

Range:

1 to 255

 

 

Default:

10

 

 

Description:

Specifies the number of errors that must occur within a fixed

 

15- minute window before an alarm is declared. This is based on

 

the threshold value for Controlled Slip Seconds, which are

 

one-second intervals containing one or more controlled slips.

 

 

Channelized Data

5-9

Page 121
Image 121
3Com S26x, S27x, S24x installation manual Threshold Value LES, Threshold Value-LCV, Threshold Value-PCV, Threshold Value-CSS