Appendix C

 

PathBuilder S24x, 26x, and 27x Switch Error Codes

Overview

 

 

 

 

Numeric LED

 

 

The 2-character numeric LED display provides system diagnostic codes to assist in

Display

troubleshooting. When the Service LED is ON, a 2-digit code on the numeric LED

 

display corresponds to a certain event or failure.

Status Display The following table lists the codes that may appear.

Error Codes

Numeric

Status

Service

Description/Comments

Display

LED

LED

 

 

 

 

 

00

Flicker

OFF

FBIST motherboard test

 

 

 

 

01-08

Flicker

OFF

FBIST I/O card test

 

 

 

 

00-08

OFF

ON

Slot # of highest priority card diagnostic failure

 

 

 

 

20

OFF

ON

Modem card failure

 

 

 

 

30

OFF

ON

PBIST—FLASH failure

 

 

 

 

31

OFF

ON

PBIST—CMEM failure

 

 

 

 

33

OFF

ON

Lab strap installed

 

 

 

 

34

OFF

ON

CMEM battery bad

 

 

 

 

40

OFF

ON

PBIST—Invalid FLASH checksum

 

 

 

 

41

OFF

ON

Alternate FLASH loaded

 

 

 

 

42

OFF

ON

Default CMEM loaded—incompatible CMEM

 

 

 

image detected

 

 

 

 

43

OFF

ON

Alternate configuration loaded

 

 

 

 

44

OFF

ON

FLASH being erased; this takes a few minutes

 

 

 

 

45

OFF

ON

Waiting for flash file; Port 6 configured at 9600

 

 

 

bps

 

 

 

 

45.

OFF

ON

Waiting for flash file; Port 6 configured at

 

 

 

19200 bps

 

 

 

 

4.5.

OFF

ON

Waiting for flash file; Port 6 configured at

 

 

 

115200 bps

 

 

 

 

46

Blinking

ON

Status OK—loading

 

 

 

 

46

No Blink

ON

Load problem— reset node and restart cold

 

 

 

load procedure.

 

 

 

 

47

OFF

ON

Copying from RAM to FLASH; this takes a

 

 

 

few minutes

 

 

 

 

PathBuilder S24x, 26x, and 27x Switch Error Codes

C-1

Page 145
Image 145
3Com S26x, S27x, S24x installation manual Error Codes, Numeric Status Service Description/Comments Display