Installing the DSU DIM
Install the DSU DIM Perform these steps to install the DSU DIM:
Step | Action | Result/Description |
|
|
|
1 | Install the DSU DIM in the DTE | The DSU option does not operate |
| position only (see Figure | if the DIM is installed in the DCE |
|
| position. |
|
|
|
2 | Set the switches properly. Refer to |
|
| “Switch Settings for Motherboard |
|
| Switches 1 and 2.” |
|
|
|
|
3 | Plug the EIM into the backplane |
|
| connector corresponding to the |
|
| DIM port containing the DSU |
|
| DIM (Port 1 or 2). Verify that the |
|
| EIM is only connected to a port |
|
| that has a DSU DIM installed. |
|
|
|
|
4 | Tighten the connector mounting |
|
| screws to provide proper |
|
| grounding and to ensure signal |
|
| integrity. |
|
|
|
|
Caution
Be sure that the telephone company plug is disconnected before you disconnect the EIM from the PathBuilder S24x, 26x, and 27x switch. Also, do not connect the telephone company plug to the EIM until you have connected the EIM to the PathBuilder S24x, 26x, and 27x switch.
Mise en Garde
Vorsicht
Das Telefonkabel muß ausgesteckt sein, bevor Sie die Verbindung zwischen dem
EIM und dem PathBuilder S24x, 26x, and 27x switch trennen. Schließen Sie das
Telefonkabel erst dann wieder in das EIM an, wenn Sie die Verbindung zwischen
EIM und PathBuilder S24x, 26x, and 27x switch wiederhergestellt haben.
PathBuilder S24x, 26x, and 27x Switch Hardware Installation |