L4421A 40-Channel Armature Multiplexer

4

L4421A D-Sub Connectors

Bank 1

Bank 1

Bank 2

For orientation, the D-sub connector end of the module is facing you.

*TSIL represents Temperature Sensor Interface Line. This line is used for temperature interface only.

WARNING As a safety feature, interlock 1 pins (17 and 33) on Bank 1 must be shorted to enable the Bank 1 Analog Bus relays to close. The optional 34921T terminal block shorts these pins for you. This feature protects inadvertent routing of high voltages from the Analog Bus to the D-sub connector of the module.

 

 

 

 

 

 

COM COM

 

 

 

 

 

 

 

 

 

 

 

 

1H

1L

2H

2L

3H

3L

1H

1L

4H

4L

14H

14L

5H

 

5L

20H

20L Interlock1

50-Pin D-Sub

1

2

3

 

4

5

6

7

8

9

10

11

 

12

13

 

14

15

16

17

TSIL* 11H 11L

7H

7L

17H

17L 13H 13L

9H

9L

19H 19L

15H 15L Interlock 1

Male Connector

 

 

18

19

 

20

21

22

23

 

24

25

26

27

28

29

 

30

31

32

 

33

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AMP AMP AMP AMP

 

 

GND 6H

6L

16H

16L 12H

12L

8H

8L

18H

18L

10H

10L

41L

41I

42L

42I

 

 

34

35

36

 

37

38

39

40

41

42

43

44

 

45

46

 

47

48

49

50

 

 

Description

Pin

 

Description

Pin

Description

Pin

 

Description

Pin

Description

Pin

1H

1

 

 

6H

 

 

35

11H

 

 

19

 

16H

 

 

37

COM1 H

7

1L

2

 

 

6L

 

 

36

11L

 

 

20

 

16L

 

 

38

COM1 L

8

2H

3

 

 

7H

 

 

21

12H

 

 

39

 

17H

 

 

23

Interlock 1

17

2L

4

 

 

7L

 

 

22

12L

 

 

40

 

17L

 

 

24

Interlock 1

33

3H

5

 

 

8H

 

 

41

13H

 

 

25

 

18H

 

 

43

GND

34

3L

6

 

 

8L

 

 

42

13L

 

 

26

 

18L

 

 

44

TSIL*

18

4H

9

 

 

9H

 

 

27

14H

 

 

11

 

19H

 

 

29

AMP 41L

47

4L

10

 

 

9L

 

 

28

14L

 

 

12

 

19L

 

 

30

AMP 41I

48

5H

13

 

 

10H

 

45

15H

 

 

31

 

20H

 

 

15

AMP 42L

49

5L

14

 

 

10L

 

 

46

15L

 

 

32

 

20L

 

 

16

AMP 42I

50

Bank 2

*TSIL represents Temperature Sensor Interface Line. This line is used for temperature interface only.

WARNING As a safety feature, interlock 2 pins (17 and 33) on Bank 2 must be shorted to enable the Bank 2 Analog Bus relays to close. The optional 34921T terminal block shorts these pins for you. This feature protects inadvertent routing of high voltages from the Analog Bus to the D-sub connector of the module.

 

 

 

 

 

 

COM COM

 

 

 

 

 

 

 

 

 

 

 

 

 

21H

21L

22H

22L

23H

23L

2H

2L

24H

24L

34H

34L

25H 25L

40H

40L Interlock 2

50-Pin D-Sub

1

2

 

3

4

5

6

7

8

 

9

10

11

12

13

14

 

15

16

17

TSIL*

31H 31L 27H 27L 37H 37L 33H

33L 29H 29L 39H 39L

35H 35L Interlock 2

Male Connector

 

 

18

 

19

20

21

22

23

24

25

26

27

28

29

 

30

31

32

33

 

 

GND

26H

26L

36H

36L

32H

32L

28H

28L 38H

38L

30H

30L

AMP AMP AMP AMP

 

 

43L

43I

44L

44I

 

 

34

35

 

36

37

38

39

40

41

 

42

43

44

45

46

47

 

48

49

50

 

 

Description

Pin

Description

Pin

Description

Pin

Description

Pin

Description

Pin

21H

 

1

 

26H

 

35

 

31H

 

 

19

 

36H

 

 

37

COM2 H

7

21L

 

2

 

26L

 

36

 

31L

 

 

20

 

36L

 

 

 

38

COM2 L

8

22H

 

3

 

27H

 

21

 

32H

 

 

39

 

37H

 

 

23

Interlock 2

17

22L

 

4

 

27L

 

22

 

32L

 

 

40

 

37L

 

 

 

24

Interlock 2

33

23H

 

5

 

28H

 

41

 

33H

 

 

25

 

38H

 

 

43

GND

34

23L

 

6

 

28L

 

42

 

33L

 

 

26

 

38L

 

 

 

44

TSIL*

18

24H

 

9

 

29H

 

27

 

34H

 

 

11

 

39H

 

 

29

AMP 43L

47

24L

 

10

29L

 

28

 

34L

 

 

12

 

39L

 

 

 

30

AMP 43I

48

25H

 

13

30H

 

45

 

35H

 

 

31

 

40H

 

 

15

AMP 44L

49

25L

 

14

30L

 

46

 

35L

 

 

32

 

40L

 

 

 

16

AMP 44I

50

L4400 User’s Guide

107

Page 117
Image 117
Agilent Technologies L4400 manual L4421A D-Sub Connectors, Bank