6L4437A General Purpose Switch

Example: Clearing the cycle count for a relay (all switch modules) The following command resets the relay cycle count on channels 7 and 16.

DIAGnostic:RELay:CYCLes:CLEar (@1007,1016)

Example: Resetting the Instrument to its power-on state The following command resets the instrument to its power- on state.

SYSTem:CPON 1

L4437A 32-Channel General Purpose Switch Hardware Description

The L4437A general- purpose switch provides independent control of:

Twenty- eight Form C (DPST) latching relays rated at 1 A

Four Form A (SPST) latching relays rated at 5 A. You can set the power- failure state for these 5 A relays. See page 128 and page 129.

N O TE

A temperature sensor on these modules triggers system interrupts

when high-carry current-induced heat on the modules reaches a

 

 

threshold of 70 oC.

 

 

L4437A Simplified Schematic

NC

NO

COM

NC

NO

COM

Channel 001

NO

(1A Form C)

 

 

COM

Channel 028

NO

(1A Form C)

 

 

COM

Channel 029 (5A Form A)

Channel 032 (5A Form A)

132

L4400 User’s Guide

Page 142
Image 142
Agilent Technologies L4400 manual L4437A Simplified Schematic, Threshold of 70 oC