©2008 Advanced Micro Devices, Inc. HD Audio Controllers Registers
AMD SB600 Register Reference Manual Proprietary Page 244
Stream Descriptor Control – RW – 24 bits
Input Stream 0 - [Mem_Reg: Base + 80h]
Input Stream 1 - [Mem_Reg: Base + A0h]
Input Stream 2 - [Mem_Reg: Base + C0h]
Input Stream 3 - [Mem_Reg: Base + E0h]
Output Stream 0 - [Mem_Reg: Base + 100h]
Output Stream 1 - [Mem_Reg: Base + 120h]
Output Stream 2 - [Mem_Reg: Base + 140h]
Output Stream 3 - [Mem_Reg: Base + 160h]
Field Name Bits Default Description
Stripe Control 17:16 0h The hardware only supports one SDO, this field has no
functional impact.
Traffic Priority 18 0b If set to “1”, it will cause the controller to generate non-
snooped traffic.
Bidirectional Direction
Control
19 0b The hardware does not support bi-direction, this field has
no impact.
Stream Number 23:20 0h T he value reflects the Tag associated with the data being
transferred on the link.
When data controlled by this descriptor is sent out over the
link, it will have this stream number encoded on the SYNC
signal.
When an input stream is detected on any of the SDIN_x
signals that match this value, the data are loaded into the
FIFO associated with this descriptor.
0000b = Reserved
0001b = Stream 1
:
1111b = Stream 15