Programming

THE FOLLOWING SECTIONS ONLY APPLY TO THE INTEGRATED

CONTROLLER COMPONENT OF THE NI-3101-SIG.

LED Disable/Enable Send_Commands

The following commands enable or disable the LEDs on the Integrated Controller.

In these examples: <DEV> = Port 1 of the device. Sending to port 1 of the NI-Controller (affects all ports).

LED Send_Commands

Command

Description

 

 

LED-DIS

Regardless of whether or not the port is active, the LED will not be lit. Issue this

Disable all LEDs (on 32 LED

command to port 1 to disable all the LEDs on the Controller. When activity

occurs on a port(s) or Controller, the LEDs will not illuminate.

hardware) for a port.

Syntax:

 

 

SEND_COMMAND <DEV>,"'LED-DIS'"

 

Example:

 

SEND_COMMAND Port_1,"'LED-DIS'"

 

Disables all the LEDs on Port 1 of the Controller.

 

 

LED-EN

When the port is active, the LED is lit. When the port is not active, the LED is

Enable the LED (on 32 LED

not lit. Issue the command to port 1 to enable the LEDs on the Controller

(default setting). When activity occurs on a port(s) or Controller, the LEDs

hardware) for a port

illuminate.

(by default).

Syntax:

 

 

SEND_COMMAND <DEV>,'LED-EN'

 

Example:

 

SEND_COMMAND System_1,'LED-EN'

 

Enables the System_1 Controller's LEDs.

 

 

RS232/422/485 Ports Channels

RS232/422/485 ports are Ports 1-6).

RS232/422/485 Ports Channels

255 - CTS push channel

Reflects the state of the CTS input if a 'CTSPSH' command was sent to the port.

154

NI-3101-SIG Signature Series NetLinx Integrated Controller

Page 160
Image 160
AMX NI-3101-SIG manual LED Disable/Enable SendCommands, RS232/422/485 Ports Channels, RS232/422/485 ports are Ports