Troubleshooting

Troubleshooting Information (Cont.)

Symptom

Solution

 

 

I can’t connect to my NI Controller

A USB cable is used for Serial communication between the PC and the

via the rear Configuration Port

Master.

using a USB cable.

• Verify the USB connectors are securely inserted into their respective

 

ports on both the rear Configuration Port (on the NI) and on the PC.

 

• The NI-3101-SIG is configured to a fixed Baud Rate of 115200.

 

 

My NetLinx devices drop offline

The benefit of setting the Ethernet mode is to keep the Master (NI

periodically when communicating

Controller) from having to auto negotiate with the Network.

over Ethernet.

On NetLinx Masters (such as those onboard the NIs), from Telnet or

 

Terminal, you can send the SET ETHERNET MODE command.

 

Examples:

 

SET ETHERNET MODE 10 HALF

 

SET ETHERNET MODE 10 FULL

 

SET ETHERNET MODE 100 HALF

 

SET ETHERNET MODE 100 FULL

 

SET ETHERNET MODE AUTO

 

The NI Controllers can utilize all of the above Ethernet modes.

 

 

When plugging the Master into a

(see above for resolution)

fixed speed hub or switch

 

(i.e. 10-BaseT Hub or Switch), the

 

hub or switch acts erratically.

 

 

 

I’m unable to connect to the

(see above for resolution)

NetLinx Master from a PC over

 

TCP/IP.

 

 

 

During the firmware upgrade

This occurs when initially upgrading the on-board Master from a

process, NetLinx Studio failed to

previous firmware build (117 or lower), to the new Web Security

install the last component.

firmware (build 300 or higher).

 

• Only upon the initial installation of the new build will be a failure of a

 

successful download of the last component. This is part of the initial

 

update procedure and will not occur during uploads of later firmware.

 

• After the last components fails to install, click Close and reboot the

 

on-board Master by selecting Tools > Reboot the Master

 

Controller > Continue to continue the process.

 

• After the last components fails to install, click Close and reboot the

 

Master by selecting Tools > Reboot the Master Controller > Continue

 

to begin the process.

 

• Refer to the Upgrading the On-board Master Firmware via an

 

IP section on page 35 for detailed procedures.

 

 

168

NI-3101-SIG Signature Series NetLinx Integrated Controller

Page 174