NetLinx Security within the Web Server

Manage System - Diagnostics

This page allows an authorized user to setup and monitor diagnostic messages coming from and going to devices available on the Online Tree. This dialog also allows the user to watch the ICSP commands being sent to/from a device. There are several different types of asynchronous notifications that can be selected for a device:port:system (D:P:S) combination. Each notification type is represented by a column in the table. All messages are displayed in the Notifications tab of the Output Display window within NetLinx Studio v 2.4.

1.Click the Manage System link (from within the System Settings section of the Navigation frame).

2.Clicking on any of the Online Tree items opens menu items with the Diagnostics button option available.

3.Click the Diagnostics button to open the Diagnostics dialog (FIG. 46).

Selected device

NetLinx Notification types

Device Configuration

dialog

FIG. 46 Diagnostics dialog (showing modify popup)

4.Use the Refresh Interval drop-down to select from the following values: 2 seconds, 5 seconds, or 10 seconds. This refresh interval allows you to select how often the messages are updated.