Configuration and Firmware Update
29
NI-3101-SIG Signature Series NetLinx Integrated Controller
10. Click Reboot from the Tools > Reboot the Master Controller dialog, and wait for the System
Master to reboot and retain the newly obtained DHCP Address. The STATUS and OUTPUT LEDs
should begin to blink alternately during the incorporation. Wait until the STATUS LED is the only
LED blinking.
11. Press Done once until the Master Reboot Status field reads *Reboot of System Complete*.
12. Complete the communication process by continuing on to the Communicating with the NI Device
via an IPsection on page 31.
Verify that these IP values are also entered into the related fields within either the
IP Settings section of the System Connection page (on the touch panel) or within the
Address field on the web browser.