NetLinx Security within the Web Server

The Device, Port, and System value ranges are 1 - 65535.

7.Within the Channel Code section, enter a valid Channel number to emulate Channel messages (i.e., Push/Release, CHON, and CHOFF) for the specified <D:P:S>.

The Channel number range is 1 - 65535.

8.Select the On or Off buttons to Emulate Channel ON (CHON) and Channel OFF (CHOFF) messages for the specified <D:P:S>.

9.Select the Push button to Emulate a push/release on the channel specified. You can click and hold down the Push button to see how the device/Master responds to the push message.

10.Within the Level Code section, enter a valid Level number and Level data value for the specified <D:P:S> and press the Send button to transmit this data.

The Level number range is 1 - 65535.

The list below contains the valid Level data types and their ranges:

Valid Level Data Types and Ranges

 

Minimum Value

Maximum Value

 

 

 

CHAR

0

255

 

 

 

INTEGER

0

65535

 

 

 

SINTEGER

-32768

32767

 

 

 

LONG

0

429497295

 

 

 

SLONG

-2147483648

2147483647

 

 

 

FLOAT

-3.402823466e+38

3.402823466e+38

 

 

 

11.Within the Command and String fields, you can enter any number of messages that can be sent as either a String or Command.

12.To Emulate sending a String or Command, type a String or Command within the corresponding field and press the Send button to transmit this data.

When entering a send command (in the context of this dialog) do not include the "send c" or "send_command" in the statement - only type what would normally occur within the quotes, but don't include the quotes either. For example to send the "CALIBRATE" send command, simply type CALIBRATE (no quotes) rather than SEND_COMMAND <dev> "CALIBRATE".

String Expressions start and end with double quotes (" "). Double quotes are not escaped; instead, they are embedded within single quotes. String expressions may contain string literals, decimal numbers, ASCII characters and hexadecimal numbers

(prepended with a $), and are comma-delimited.

String Literals start and end with single quotes ( ' ). To escape a single quote, use ''' (three single quotes).

NI-3101-SIG Signature Series NetLinx Integrated Controller

69

 

 

Page 75
Image 75
AMX NI-3101-SIG manual Valid Level Data Types and Ranges, Minimum Value Maximum Value