Replacing the Timekeeper Battery

The NI-3101-SIG uses a combination lithium battery and clock crystal package called a Timekeeper. Only one Timekeeper unit is installed within a given NI-3101-SIG. The battery can be expected to have up to 3 years of usable life under very adverse conditions. Actual life is appreciably longer under normal operating conditions. This calculation is based on storing the unit without power in 50° C (120° F) temperature until battery levels are no longer acceptable. The part number for a replacement battery is 57-0032.

To replace the Timekeeper battery:

1.Discharge the static electricity from your body by touching a grounded metal object.

2.Unplug all the connectors from the device.

3.Remove the rear panel from the device, and then disconnect the NXI control cable and remove the Master card.

4.Locate the battery behind the Configuration Port on the circuit board.

5.Carefully slide the battery out of its socket and insert the new battery.

6.Plug the 2-pin 3.5 mm mini-Phoenix PWR (green) connector to reapply power. Wait approximately 1 minute, then remove the PWR connector again.

7.Carefully slide the other battery out of its socket and insert the new battery

8.Re-connect the NXI control cable to the Master card.

9.Replace and secure the rear faceplate using the mounting screws and reconnect all communication connectors.

10.Reconnect the 12 VDC power supply to the respective PWR connector and apply power.