Connections and Wiring

Wiring a power connection

To use the 2-pin 3.5 mm mini-Phoenix connector with a 12 VDC-compliant power supply, the incoming PWR and GND cables from the external source must be connected to their corresponding locations on the connector (FIG. 4).

1.Insert the PWR and GND wires on the terminal end of the 2-pin 3.5 mm mini-Phoenix cable. Match the wiring locations of the +/- on both the power supply and the terminal connector.

2.Tighten the clamp to secure the two wires. Do not tighten the screws excessively; doing so may strip the threads and damage the connector.

3.Verify the connection of the 2-pin 3.5 mm mini-Phoenix to the external 12 VDC-compliant power supply.

PWR +

GND -

To the Integrated Controller

FIG. 4 2-pin mini-Phoenix connector wiring diagram (direct power)

Power Supply

Using the 4-pin mini-Phoenix connector for data and power

Connect the 4-pin 3.5 mm mini-Phoenix (female) captive-wire connector to an external NetLinx device as shown in FIG. 5.

To the Integrated Controller’s

To the external AXlink device

AXlink/PWR connector

Top view

GND -

AXP/TX

AXM/RX

PWR +

GND -

AXP/TX

AXM/RX

PWR +

Top view

FIG. 5 Mini-Phoenix connector wiring diagram (direct data and power)

NI-3101-SIG Signature Series NetLinx Integrated Controller

13

 

 

Page 19
Image 19
AMX NI-3101-SIG manual Wiring a power connection, Using the 4-pin mini-Phoenix connector for data and power