Programming

IR/Serial Send_Commands (Cont.)

Command

Description

 

 

POD

Channel 255 changes are enabled. This command is used in conjunction with

Disable previously active

the I/O Link command.

Syntax:

'PON' (power on) or 'POF'

(power off) command

SEND_COMMAND <DEV>,"'POD'"

settings.

Example:

 

 

SEND_COMMAND IR_1,"'POD"

 

Disables the 'PON' and 'POF' command settings on the IR_1 device.

 

 

POF

If at any time the IR sensor input reads that the device is ON (such as if

Turn Off a device connected

someone turned it on manually at the front panel), IR function 28 (if available)

or IR function 9 is automatically generated in an attempt to turn the device back

to an IR port based on the

OFF. If three attempts fail, the IR port will continue executing commands in the

status of the corresponding

buffer.

I/O Link input.

If there are no commands in the buffer, the IR port will continue executing

 

 

commands in the buffer and trying to turn the device OFF until a 'PON' or 'POD'

 

command is received. If the IR port fails to turn the device OFF, a PUSH and

 

RELEASE is made on channel 254 to indicate a power failure error. You can

 

only use the 'PON' and 'POF' commands when an IR device has a linked

 

I/O channel. Channel 255 changes are disabled after receipt of this command.

 

You can only use the 'PON' and 'POF' commands when an IR device has a

 

linked I/O channel.

 

Syntax:

 

SEND_COMMAND <DEV>,"'POF'"

 

Example:

 

SEND_COMMAND IR_1,"'POF'"

 

Sends power down IR commands 28 (if present) or 9 to the IR_1 device.

 

 

PON

If at any time the IR sensor input reads that the device is OFF (such as if one

Turn On a device connected

turned it off manually at the front panel), IR function 27 (if available) or IR

function 9 is automatically generated in an attempt to turn the device back ON.

to an IR port based on the

If three attempts fail, the IR port will continue executing commands in the buffer

status of the corresponding

and trying to turn the device On.

I/O Link input.

If there are no commands in the buffer, the IR port will continue trying to turn

 

 

the device ON until a 'POF' or 'POD' command is received. If the IR port fails to

 

turn the device ON, a PUSH and RELEASE is made on channel 254 to indicate

 

a power failure error.

 

You can only use the 'PON' and 'POF' commands when an IR device has a

 

linked I/O channel. Channel 255 changes are disabled after receipt of this

 

command.

 

Syntax:

 

SEND_COMMAND <DEV>,"'PON'"

 

Example:

 

SEND_COMMAND IR_1,"'PON'"

 

Sends power up IR commands 27 or 9 to the IR_1 port.

 

 

162

NI-3101-SIG Signature Series NetLinx Integrated Controller

Page 168
Image 168
AMX NI-3101-SIG manual Pod, Pof, Pon