3.Type n to display the next page of System Log information, or type q to quit.

Clearing the System Log

Use the following procedure to clear all entries from the current System Log:

1.Open the System Log Menu by typing l in the System Utility Menu.

2.Type c to clear the current System Log.

New entries will accrue as events occur.

3.14.5 Bootstrap Configuration

The Bootstrap Configuration Menu displays, and allows the user to change, the bootstrap parameters used for loading the software for the switch at startup, and for downloading a new version of software when one is issued.

To access the Bootstrap Configuration Menu, type b in the System Utility Menu. If the Load Mode is set to Local, a screen similar to that below will appear.

IntraCore 35160-T Bootstrap Configuration Menu

Bank 1 Image Version/Date: 1.20B/Jun 17 2003 20:41:25 (Running)

Bank 2 Image Version/Date: 1.10 /May 20 2003 18:01:54

Load Mode: Local

Boot Bank: 1

<Cmd> <Description>

rSet Load Mode to REMOTE

a Toggle Boot Bank

o Commence Bootstrap Sequence

q Return to previous menu

root>

When the switch is powered on, it loads its software via one of two methods: locally (via its internal flash memory, which is the default setting) or remotely over the network. The user can change the bootstrap configuration from this menu. See Appendix F BootP Configuration for more information on BootP and the Remote mode.

43

Page 43
Image 43
Asante Technologies 35160 user manual Bootstrap Configuration, Clearing the System Log