Asante Technologies 35160 user manual System Log, Scheduling a System Reset

Models: 35160

1 88
Download 88 pages 15.65 Kb
Page 42
Image 42

Scheduling a System Reset

The user can schedule the switch to automatically perform a reset from one second up to 24 hours (86,400 seconds) in advance.

To schedule a reset, use the following procedure:

1.Open the System Reset Menu by typing r in the System Utility Menu.

2.Type s to schedule a reset time (within the specified range).

3.Enter the number of seconds the switch will wait before it automatically resets. Important! The maximum number of seconds that can be entered is 86,400 (24 hours).

4.Press Enter. The switch will reset automatically after the number of seconds specified.

3.14.4 System Log

The switch’s system log records and displays any major system events on the switch, such as fatal errors, plugging in or removing a module, and so on.

To view the system log, use the following procedure:

1.Type l in the System Utility Menu. The System Log Menu appears, as shown below.

IntraCore 35160-T System Log Menu

<Cmd> <Description>

lDisplay System Log

c Clear System Log

q Return to previous menu

root>

2.Type l in the System Log Menu to display the current system log.

The system log displays any major system events that have occurred on the switch. If no major events have occurred, “System up” messages are displayed.

IntraCore 35160-T System Log Summary

==============================================================================

1.08/22/2002 12:53:30pm System up

2.08/22/2002 12:55:52pm System up

3.08/22/2002 02:38:50pm System up

4.08/22/2002 02:43:38pm System up

5.08/22/2002 02:47:21pm System up

6.08/22/2002 02:47:54pm Spanning Tree Task Disabled

7.08/22/2002 02:52:34pm System up

8.08/22/2002 02:55:37pm Primary Power unit failed !

9.08/22/2002 02:55:39pm Primary Power unit failed !

10.08/22/2002 02:55:41pm Primary Power unit failed !

11.08/22/2002 02:55:44pm Primary Power unit failed !

12.08/22/2002 02:55:46pm Primary Power unit failed !

13.08/22/2002 02:55:48pm Primary Power unit failed !

14.08/22/2002 02:55:51pm Primary Power unit failed !

15.08/22/2002 02:56:01pm Primary Power unit failed !

16.08/26/2002 09:20:02am System up

17.08/26/2002 09:23:42am Spanning Tree Task Enabled

18.08/26/2002 11:30:00am System up

19.08/26/2002 01:40:20pm System up

20.08/26/2002 01:46:00pm System up

End of system log,

Quit

Note: The system log holds a maximum of 64 entries.

42

Page 42
Image 42
Asante Technologies 35160 user manual System Log, Scheduling a System Reset