Chassis Installation/Placement
Chassis Installation/Placement
The IntraCore 8000 can be installed in a standard
IImportant: The equipment rack or desk on which you install your IntraCore 8000 must be secure and stable. Equipment racks must be fastened to the floor; desks must be resting on a flat, stable surface.
Installation in an Equipment Rack
To install the unit in an equipment rack, use the following procedure.
Safety Precautions for Rack Installation
IImportant! Before continuing, disconnect all cables from the IntraCore 8000. Also, do not install any optional modules you have purchased until the switch has been installed in the rack.
Equipment Rack Guidelines
Guideline | Specification |
|
|
Size | Width; 17.75 inches (45.09 cm). |
| Depth: 19.25 inches (48.9 cm) to 32 inches (81.3 cm). |
|
|
Stability | Rack must be bolted to the floor. Mount heavier units at the bottom of the |
| rack. If the IntraCore 8000 is the only unit, mount it the bottom of the |
| rack.. |
|
|
Ventilation | Ensure that the rack is installed in a room where the temperature remains |
| below 40° C (104° F). Ensure also that there are no obstructions, such as |
| other equipment or cables, blocking airflow to or from the IntraCore 8000 |
| vents. |
|
|
Clearance | In addition to providing clearance for ventilation, ensure that there is ade- |
| quate clearance for servicing the modules of the IntraCore 8000 from the |
| front. |
|
|