Configuration

Loading Software Locally

The IntraCore 8000 will always boot locally unless you set it to boot load remotely. It would then download the new image code and reset to load locally.

1 Open the Bootstrap Configuration Menu by typing b in the Configuration Menu.

2 Type a in the Bootstrap Configuration Menu if you need to toggle the Boot Bank setting for the next boot. Typi- cally, you will want to set the boot bank to be the one on which the latest version of the Image resides.

The IntraCore 8000 is set to load software locally from its flash memory. This occurs whenever the unit is powered on or reset.