Image File Downloading Configuration

Current Settings

Table 3-11 describes the settings shown in the X/Y/Z Modem Image File Downloading Menu.

Setting

Description

 

 

Bank 1 Image Version/

The version number and compilation date of runtime code that

Date

is stored in memory Bank 1 on the IntraCore 8000.

 

 

Bank 2 Image Version/

The version number and compilation date of runtime code that

Date

is stored in memory Bank 2 on the IntraCore 8000.The (Run-

 

ning) designation indicates that the runtime code is currently

 

running on this Bank.

 

 

Download Protocol

Current setting of the IntraCore 8000’s serial download proto-

 

col.

 

 

Current Baud Rate

Transmission rate for the IntraCore 8000’s serial port.

 

 

Destination Bank

Number of the memory bank where the image file will down-

 

load.

 

 

Table 3-11 X/Y/Z Modem Image File Downloading settings

Performing a Software Upgrade

Use the following procedure to upgrade the IntraCore 8000 software through its serial (console) port.

1 In the Image File Download Configuration Menu, type x to open the X/Y/Z Modem Image File Downloading Menu.

2 Type x, y, or z to select the corresponding modem proto- col.

KNote: For information about these protocols, see the manual for your communications software.

3 Type c to select the console baud rate. The Baud Rate Set- ting Menu appears, as shown in Figure 3-24. The maxi- mum baud rate currently supported is 57,600 bps.

Page 3-43