Installation and Setup

Equipment Rack Installation Procedure

To mount the IntraCore 8000 in an equipment rack:

1

2

Place the IntraCore 8000 on a flat, stable surface.

Locate a rack-mounting bracket (supplied) and place it over the mounting holes on one side of the unit.

3 Insert six screws (supplied) into the holes and tighten with a Phillips screwdriver. Do not use fewer than six screws for this mounting.

4 For the other side of the unit, repeat the two previous steps.

5

6

Place the unit in the equipment rack.

Secure the unit by screwing its mounting brackets to the equipment rack. Use a minimum of four screws for this purpose.

IImportant! Make sure the unit is supported until all the mounting screws for each bracket are secured to the equipment rack. Failure to do so could cause the unit to fall, resulting in personal injury or damage to the unit, or both.

7 Proceed to the section, “Installing Port Expansion Mod- ules.”

Free-Standing/Desktop Placement

The IntraCore 8000 has four rubber feet on the bottom of the case that allow for free-standing placement of the unit.

For free-standing/desktop placement:

1 Attach the four rubber pads (supplied) to the bottom of each corner of the IntraCore 8000 chassis.

2 Place the unit on a flat surface with a minimum area of 17.1” x 13.5” (434.3 mm x 342.9 mm) and support capac- ity of 22 lbs (10 kg).

3 Make sure there is enough ventilation space between the IntraCore 8000 and surrounding objects.