Configuration

Current Baud Rate: 9600 bps

Please select one from the following baud rate settings, or press any other key to quit:

WARNING: The user must use the same baud rate setting of the terminal after he/she confirms to change the baud rate setting of the console in order to work correctly.

<Cmd> <Description>

aSet Baud Rate to 1200 bps

bSet Baud Rate to 2400 bps

cSet Baud Rate to 4800 bps

dSet Baud Rate to 9600 bps

eSet Baud Rate to 19200 bps

fSet Baud Rate to 38400 bps

gSet Baud Rate to 57600 bps

Choice>

Figure 3-24 Baud Rate Menu

4 Select one of the options in the above screen to select the required baud rate, and confirm it by typing y.

5

6

KNote: The baud rate default for console management is 9600 bps; in most cases the default will match the rate for the connected terminal. If you change the baud rate for the console port, the screen will display gartbled data unless the connected terminal is set to the same rate.

Type a to select the Destination Bank.

To download the image file, use any serial communica- tions software such as Procomm Plus, HyperTerminal, ZTerm, etc. For file transfer instructions, follow the instruction manual of the serial communications soft- ware.

KNote: The terminal on which the serial communica- tions software is running must have the same baud rate as the IntraCore 8000 management module con- sole. The connection from the terminal to the switch console port must be an RS232C straight-through cable.

Page 3-44

Page 78
Image 78
Asante Technologies 8000 user manual Baud Rate Menu