Chapter 7

Table 7-11. USP Dialog Box - Frame Relay Parameters (Continued)

Field

Description

 

 

Oper Status

The operational status of the interface.

 

Possible statuses include:

 

Up - The interface is up and can transmit

 

and receive packets.

 

Down - The interface is down due to

 

some failure, and cannot transmit or

 

receive packets.

 

Testing - The interface is in testing mode

 

and cannot transmit or receive regular

 

data.

 

Standby - The interface is a backup

 

interface and cannot transmit or receive

 

packets unless the primary interface it

 

backs up fails.

 

Disabled - The interface is disabled. It

 

cannot transmit or receive packets.

 

Partially Down - The interface is up.

 

However, some interfaces (or PVCs)

 

layered on top of this interface are Down.

 

Some packets can be transmitted and

 

received.

 

 

MTU (octets)

The size (in octets) of the largest datagram

 

that can be sent via the interface.

 

 

Last Fault Message

The type of error last occurring on the

 

interface. Possible values are:

 

• Unknown Error

 

• Receive Short

 

• Receive Long

 

• Illegal Address

 

• Unknown Address

 

• DLCMI Protocol Error

 

• DLCMI Unknown IE

 

• DLCMI Sequence Error

 

• DLCMI Unknown Rpt

 

• No Error Since Reset

 

 

Time Since Fault

The amount of time the system was up before

 

the last error occurred.

 

 

116

Avaya C360 Manager User Guide

Page 130
Image 130
Avaya C360 manual That can be sent via the interface