Setup 5-7MN1853
Configuring the Distance Unit [ DUi ]
EDIT > SETUP > MECH > DIST
Value: inch
Range: inch or mm
– Axis One Dist Units –
←↑ inch ↓→
Select value, press ENTER
This sets the distance units and unit label. All distance values are
expressed in the units selected here.
Configuring Units of Velocity [ VUi ]
EDIT > SETUP > MECH > VEL
Value: in/s
Range: in/s or in/min
– Axis One Vel Units –
←↑ in/s ↓→
Sets the velocity units. All velocity values will be expressed in these units.
Select value, press ENTER
Configuring Maximum Velocity [ MVr ]
EDIT > SETUP > MECH > VMAX
Value: 100.0 in/s
Range: 0–9999999.0
– Axis One MAX Vel –
←↑ 100.0 in/s ↓→
Sets the top speed of your motor. (Limits the speed from LinStep+ to
prevent accidental damage to your mechanics.)
Select value, press ENTER
Configuring Acceleration Units [ AUi ]
EDIT > SETUP > MECH > ACCEL
Value: sec
Range: seconds or in/s2
– Axis One Accel Units –
←↑ sec ↓→
Sets the acceleration (and deceleration) units. All acceleration and
deceleration values will be expressed in these units. You can specify
acceleration as a rate, or in time–to–accelerate to full speed.
Select value, press ENTER