4-8 Keypad Operation MN1853

Edit, Setup Submenu Table shows the structure within the EDIT, SETUP submenu.

Table 4-2 Edit, Setup Submenu
Submenu Setup Parameter Description of Setup Parameter
TYPE Motor parameters
MOTOR DRES Drive resolution
MOTOR DIR Direction of travel
MODE Select open/closed loop mode
ERES Encoder resolution
FOLERR Following error
ENC INRANGE Position maintenance window
PMGAIN Position maintenance gain
PMMAX Position maintenance maximum velocity
DIST Distance Units
PITCH The spacing between the photo etched teeth of the motor platen.
VEL Speed units
MECH VMAX Critical speed limit
ACCEL Acceleration units
AMAX Maximum rate of acceleration
INPUTS Input functions
OUTPTS Output functions
I/O OPTOS OPTO module configuration
I/O OUTSTS Configure output states during Powerup, Fault, and Stop/Kill command.
LIMITS Configure EOT polarity (N.O. or N.C.)
ACCEL Jog acceleration
JOG LOVEL Low jog velocity
JOG
HIVEL High jog velocity
ENABLE Enable/disable jog in RUN menu
MODE Homing method
EDGE Edge of home switch
HOME SWITCH Type of home switch
HOME OFFSET Position counter offset
DIR Final homing direction (positive or negative)
PWRUP Program to run on power up, if any
PROG SCAN How to scan program select inputs
PROG DELAY Program Select debounce time
RS232C ECHO Echo characters
RS232C
UNIT# Serial address
DISP Display mode (not currently implemented)
MISC STOPRATE Decel rate when stop input activated
MISC
TEST Enable Test Menu (not currently implemented)
PASWRD Password setup for operator/administrator access