Configuring Acceleration Maximum [ AMr ]

EDIT > SETUP > MECH >AMAX

Value: 0.002 sec

Range: 0.002–9999999.0

Sets the maximum acceleration and deceleration limit for programmed move profiles. Programmed accelerations and decelerations for moves will be limited by this parameter (like VMAX for velocity).

– Axis One MAX Accel –

←↑

0.002 sec ↓→

Select value, press ENTER

Configure the I/O

Each input and output is easily defined with the I/O SETUP menus. When the I/O’s are defined, it is a good idea to write down the configuration for later reference.

Configuring Input Definition [ IDaaaaaaaa ]

EDIT > SETUP > I/O > INPUTS

Value: IUUUUUUU

Range: N/A

Each input is easily configured using the keypad as described in Table 5-1. The function of each input channel is indicated by a letter at the bottom of the display.

Note: Use the and keys to select an Input. Then use ↑↓ to select the definition for each input (described in Table 5-1).

Table 5-1

IN1:Unassigned

IUUUUUUU ←↑↓→

Select value, press ENTER

Char

Keypad Display

Input Character Description

B

Bin Program

Binary Program Select – allows remote program selection and execution from

 

 

a PLC, switches, or outputs from a PC. Up to 255 programs may be selected

 

 

using 8 binary inputs. The lowest numbered input becomes the least

 

 

significant selection bit (i.e., input #1 is less significant than input #2). The act

 

 

of configuring an input as a program select input also enables binary program

 

 

select mode.

 

 

 

C

BCD Program

BCD Program Select – allows remote program selection and execution using

 

 

a PLC, switches, or outputs from a computer. Up to 99 programs may be

 

 

selected using BCD inputs. The lowest numbered input becomes the least

 

 

significant selection bit (i.e., input #1 is less significant than input #2).

 

 

 

c

Clear Command Buffer

Clear Command Buffer – Clears the terminal input buffer and buffered

 

 

command buffer.

 

 

 

D

Disable Keypad

Lock (Disable) Keypad – When activated, the keypad is disabled allowing NO

 

 

user access. The keypad resumes normal operation, subject to the DIP

 

 

switch pattern, when the input is released.

5-8 Setup

MN1853

Page 47
Image 47
Baldor MIN1853 manual Configure the I/O, Char Keypad Display Input Character Description