Setup 5-15MN1853
Configuring Home Edge [ HEi ]
EDIT > SETUP > HOME > EDGE
Value: NEGATIVE
Range: NEGATIVE, POSITIVE
Axis One Home Edge
NEGATIVE
Sets the home switch active on the negative edge or positive edge
of the encoder index channel. Use the and keys to select.
Select value, press ENTER
Configuring Home Switch [ HSi ]
EDIT > SETUP > HOME > SWITCH
Value: Norm Open
Range: Norm Open or Norm Closed
Axis One Home Switch
Norm Open
Selects the type of switch used for the home input. Use the and
keys to select.
Select value, press ENTER
Configuring Home Offset [ HOr ]
EDIT > SETUP > HOME > OFFSET
Value: 0.0 {Distance Units}
Range: 0.0999999999.0
Axis One Home Offset
0.0 in
Sets the offset from home position for the real home position. After
a successful homing move, the home position (the factory set home
position is +0.0000) is set to the offset value. Use the numeric keys
to enter a value.
This allows multiple systems to have identical programs and only
change the home offset value for each machine.
Select value, press ENTER
Configuring Home Direction [ HFi ]
EDIT > SETUP > HOME > DIR
Value: POSITIVE
Range: NEGATIVE, POSITIVE
Axis One Final Dir
Positive
Sets the direction for the Go Home (GH) move. This is the direction used to
search for the encoder index mark (Z channel) after the appropriate home
switch edge is found.
Select value, press ENTER