Configure Power–up Program

The Program Setup menu allows selection of (1) a program to be immediately run when LinStep+ is powered–up and (2) scanning conditions for the BCD or binary program select inputs.

Action

 

 

Display

 

 

Comments

 

 

 

 

 

 

 

Press F1 (PROG) key for more

 

 

 

 

 

Select a sub–menu, press F1 (PROG),

 

SETUP

 

sub menu selections.

 

 

 

 

F2 (RS232), or F3 (MISC).

 

PROG

RS232

MISC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Configuring Power–up Program [ PUi ]

EDIT > SETUP > PROG > PWR–UP

Value: 0

Range: 0–400

Sets the program to run at power–up. The selected program is executed (run) when power is applied or after a reset. If a value of 0 is entered in this menu, or if the specified program does not exist, no program is run. Use numeric keys to enter program number.

Configuring Scan Conditions [ SNaaaaaaaa ]

EDIT > SETUP > PROG > SCAN

Value: YYYYYYY

Range: YYYYYYY, NNNNNNN

– Power Up Program – PROGRAM:0

Select value, press ENTER

– Stop After Scan – ←↑ YYYYYYY ESC ↓→

Select value, press ENTER

Selects the events that cause the control to stop scanning program–select configured inputs. The selected event is listed to the right of these 7 characters: ESCape, STOP, LIMIT+, LIMIT–, KILL, FAULT or INTerrupt.

If a stop–scan event is enabled, the system will stop scanning the inputs for program numbers when that condition occurs. To resume scanning, a reset (Warm Boot input or cycle power Off then On) must be given. This option has no effect if the inputs are not configured as program select inputs (either BCD or Binary).

Configuring Scan Delay [ DYi ]

EDIT > SETUP > PROG > DELAY

Value: 100

Range: 0–99999

– Scan Debounce – DELAY (ms):100

Select value, press ENTER

Sets the amount of time required for the program select inputs (BCD or Binary) to remain stable before they are valid. The minimum time is 2 ms. If program select inputs are not stable for a time equal to or greater than the specified delay, the program will not be executed. Use the numeric keys to enter a value in ms. Note: See Data Valid Input Configuration for an alternate approach.

5-16 Setup

MN1853

Page 55