5-16 Setup MN1853
Configure Power–up ProgramThe Program Setup menu allows selection of (1) a program to be immediately run
when LinStep+ is powered–up and (2) scanning conditions for the BCD or binary
program select inputs.
Action Display Comments
Press F1 (PROG)key for more
sub menu selections. –↑SETUP↓–
PROG RS232 MISC
Select a sub–menu, press F1 (PROG),
F2 (RS232), or F3 (MISC).
Configuring Power–up Program [ PUi ]
EDIT > SETUP > PROG > PWR–UP
Value: 0
Range: 0–400
– Power Up Program –
PROGRAM:0
Sets the program to run at power–up. The selected program is
executed (run) when power is applied or after a reset. If a value of 0
is entered in this menu, or if the specified program does not exist, no
program is run. Use numeric keys to enter program number.
Select value, press ENTER
Configuring Scan Conditions [ SNaaaaaaaa ]
EDIT > SETUP > PROG > SCAN
Value: YYYYYYY
Range: YYYYYYY, NNNNNNN
– Stop After Scan –
←↑ YYYYYYY ESC ↓→
Selects the events that cause the control to stop scanning program–select
configured inputs. The selected event is listed to the right of these 7
characters: ESCape, STOP, LIMIT+, LIMIT–, KILL, FAULT or INTerrupt.
If a stop–scan event is enabled, the system will stop scanning the inputs for
program numbers when that condition occurs. To resume scanning, a reset
(Warm Boot input or cycle power Off then On) must be given. This option
has no effect if the inputs are not configured as program select inputs (either
BCD or Binary).
Select value, press ENTER
Configuring Scan Delay [ DYi ]
EDIT > SETUP > PROG > DELAY
Value: 100
Range: 0–99999
– Scan Debounce –
DELAY (ms):100
Sets the amount of time required for the program select inputs (BCD or Binary) to
remain stable before they are valid. The minimum time is 2 ms. If program select
inputs are not stable for a time equal to or greater than the specified delay, the
program will not be executed. Use the numeric keys to enter a value in ms.
Note: See Data Valid Input Configuration for an alternate approach.
Select value, press ENTER