General Specifications

Description

 

 

Unit

LX1P1A07F9

 

LX1P1A03F9

 

LX1P2A03F9

 

 

 

 

 

 

 

 

 

Input Voltage Range

Nominal

VAC

 

115

 

230

 

Minimum

 

 

92

 

184

 

Maximum

 

 

132

 

265

 

 

 

 

 

 

 

 

Input Frequency

 

 

Hz

 

50/60 ± 5%

 

 

 

 

 

 

 

 

 

 

Nominal Output Bus

Nominal

VDC

 

160

 

320

(@ 115 / 230 input)

Minimum

 

 

88

 

176

 

Maximum

 

 

220

 

440

Adjustable in 0.1A increments

 

 

 

 

 

 

ARMS

0.1 – 7.9

 

0.1 – 3.0

 

0.1 – 3.9

Resolution

 

 

in (mm)

 

5.5 x 10–5(1.02 x 10–3)

 

Efficiency

 

 

%

 

85

 

 

 

 

 

 

 

 

 

Motor Inductance

 

 

mH

 

2 – 60

 

8 – 240

 

 

 

 

 

 

 

 

Switching Frequency

 

 

kHz

 

20

 

 

 

 

 

 

 

Encoder

 

 

Optically Isolated, differential line driver, 5VDC, 500 KHz

 

 

 

 

Max (2 MHz post quadrature)

 

 

 

 

 

 

 

Inputs

 

 

8 – Programmable + 2 Limit and 1 Home inputs.

(24VDC

 

 

 

 

maximum – optically isolated 3mA sink current at 0.7Volts)

 

 

 

 

 

 

Output Power

 

 

12VDC @ 250mA (Pull–ups)

 

 

 

 

 

5VDC @ 200mA (encoder)

 

 

 

 

 

Programmable Outputs

8 – Open collector (100mA maximum sink current).

 

 

 

 

 

 

Programming

 

 

Keypad or Serial communications

 

 

 

 

 

Operating Temperature

° F 〈° C)

32 to 100 (0 to 40); 122 (50) Maximum

 

 

 

 

 

 

 

Operating Altitude

 

 

ft (m)

 

8300 (2540) Maximum

 

 

 

 

 

 

 

 

Storage Temperature

 

 

° F 〈° C)

 

–13 to 158 (–25 to 70)

 

 

 

 

 

 

 

 

Humidity (non–condensing)

%

 

 

10–90

 

 

 

 

 

 

Shock

 

 

 

10G (according to DIN IEC 68–2–6/29)

 

 

 

 

 

Vibration

 

 

 

1G @ 10 – 150 Hz (according to DIN IEC 68–2–6/29)

 

 

 

 

 

 

 

Protection & Indicators

 

Description

 

 

 

 

 

 

 

 

LED Indications

 

 

Green – Normal operation; Red – Fault condition; Amber – FLASH

 

 

 

fault Protection

 

 

 

 

 

 

 

 

Short Circuit

 

 

Disable on phase–to–phase, or phase–to–ground detected

 

 

 

 

 

Undervoltage

 

 

Disable if supply drops below 90 VAC

 

 

 

 

 

 

 

 

 

Over Temperature

 

 

Disable if heatsink > 70 ° C

 

 

 

 

 

 

 

 

 

Interlock

 

 

Disable if interlock connection broken

 

 

 

 

 

Regen/Overvoltage

 

 

Disable if bus voltage exceeds 220 VAC on 115 VAC units, 440 VAC

 

 

 

on 230 VAC unit

 

 

 

 

 

 

 

 

 

 

 

 

 

8-2 Specifications & Product Data

MN1853

Page 97