4.6.2 CAN2 (Baldor CAN) - X18

Baldor CAN connections are made using the breakout module connector X18.

18

Location

Breakout module, connector X18

 

 

 

Pin

Name

Description

 

 

 

1

-

(NC)

 

 

 

2

-

(NC)

 

 

 

3

-

(NC)

 

 

 

4

CAN2 0V

Ground/earth reference for CAN signal

 

 

 

5

CAN2 V+

CAN remote node power V+ (12-24V)

 

 

 

6

-

(NC)

 

 

 

7

CAN2+

CAN channel 2 positive

 

 

 

8

CAN2-

CAN channel 2 negative

 

 

 

Description

Baldor proprietary CAN interface using a RJ45 connector.

If NextMove PCI is at the end of the Baldor CAN network a termination resistor must be connected by fitting the termination jumper J7, labelled “BC Term”, on the breakout module.

4-22 Input / Output

MN1903

Page 38
Image 38
Baldor MN1903 installation manual 2 CAN2 Baldor can, Baldor proprietary can interface using a RJ45 connector