Symptom

Check

 

 

Motor runs uncontrollably

Check that the axis’ corresponding encoder and demand

when controller is switched

signals are connected to the same axes of motion. Check

on and servo loop gains are

the demand to the drive is connected with the correct

applied or when a move is

polarity.

set in progress. Motor then

 

stops after a short time.

Check that for a positive demand signal, a positive increase

 

in axis position is seen. The MintMT ENCODERMODE

 

keyword can be used to change encoder input direction.

 

The MintMT DACMODE keyword can be used to reverse DAC

 

output polarity.

 

Check that the maximum following error is set to a

 

reasonable value. For setting up purposes, following error

 

detection may be disabled by setting FOLERRORMODE = 0.

 

 

Motor is under control, but

Servo loop gains may be set incorrectly. See sections 5.4.2

vibrates or overshoots

to 5.6.

during a move.

 

 

 

Motor is under control, but

Using an oscilloscope at the breakout module connectors,

when moved to a position

check:

and then back to the start it

 

does not return to the same

H all encoder channels are clear signals and free from

position.

electrical noise;

 

H they are correctly wired to the controller;

 

H when the motor turns, the two square wave signals are

 

90 degrees out of phase. Also check the complement

 

signals.

 

Ensure that the encoder lead uses shielded twisted pair

 

cable and that the shield is attached to the shield connection

 

only at the breakout module end.

 

Verify that the breakout module and drive are correctly

 

grounded to a common earth point.

 

 

6-4 Troubleshooting

MN1903

Page 78
Image 78
Baldor MN1903 installation manual Output polarity