HTerminators must only be fitted at both ends of the network, not at intermediate nodes.

HThe 0V connection of all of the nodes on the network must be tied together through the CAN cabling. This ensures that the CAN signal levels transmitted by NextMove PCI or CAN peripheral devices are within the common mode range of the receiver circuitry of other nodes on the network.

4.6.1CAN1 (CANopen) - X17

CANopen connections are made using the breakout module connector X17.

15

6 9

Location

Breakout module, connector X17

 

 

 

Pin

Name

Description

 

 

 

1

Shield

Cable shield

 

 

 

2

CAN1-

CAN channel 1 negative

 

 

 

3

CAN1 GND

CAN1 Ground / earth reference

 

 

 

4

-

(NC)

 

 

 

5

-

(NC)

 

 

 

6

-

(NC)

 

 

 

7

CAN1+

CAN channel 1 positive

 

 

 

8

-

(NC)

 

 

 

9

CAN1 V+

CAN1 power (12-24V)

 

 

 

Description

CANopen interface using a 9-pin male D-type connector with CiA standard DS102 pin configuration

If NextMove PCI is at the end of the CANopen network the termination resistor must be connected by fitting the termination jumper J8, labelled “CO Term”, on the breakout module.