6.2 NextMove PCI indicators

6.2.1 Status and CAN LEDs

The backplate of the NextMove PCI contains four LEDs. S1 and S2 represent general status information. C1 and C2 are CAN traffic indicators. The LEDs may illuminate red or green and can be continuous or flashing.

C1

S1

C2

S2

LED State(s)

Meaning

 

 

All off

NextMove PCI is not powered.

 

 

All red

In hardware reset (see section 4.8).

 

 

All green,

In software reset, with no errors (see section 4.8).

cycling

 

 

 

All red,

In software reset, Power On Self Test (POST) error has occurred.

cycling

 

 

 

S1 green,

Program is running OK.

flashing

 

 

 

S1 red,

Program is running, but there is an initialization error.

flashing

 

 

 

S1 red,

Asynchronous error - for example, a limit switch has been activated.

flashing fast

 

 

 

S1 green,

Miscellaneous error - for example, the output driver board is not

flashing fast

working.

 

 

All green,

Updating firmware.

flashing

 

 

 

All red, turn off

POST is in operation (after reset).

in sequence:

 

C1, S1, S2, C2

 

 

 

C2 green,

Message received on CAN2 bus.

flashing

 

 

 