Black Box 1101 To set the Manager Address field, Config --set config.system.snmp.address2=w.x.y.z

Models: 1101 1102 Secure Device Servers

1 164
Download 164 pages 30.63 Kb
Page 146
Image 146

1101 and 1102 Secure Device Servers

If the standard system firewall configuration is not adequate for your needs you can bypass it safely by creating a file at /etc/config/filter-customcontaining commands to build a specialized firewall. This firewall script will run whenever the LAN interface is brought up (including initially) and will override any automated system firewall settings.

Below is a simple example of a custom script that creates a firewall using the iptables command. Only incoming connections from computers on a C-class network 192.168.10.0 will be accepted when this script is installed at /etc/config/filter-custom.Note that when this script is called, any pre- existing chains and rules have been flushed from iptables:

#/bin/sh

#Set default policies to drop any incoming or routable traffic

#and blindly accept anything from the 192.168.10.0 network. iptables –-policy FORWARD DROP

iptables –-policy INPUT DROP iptables –-policy OUTPUT ACCEPT

#Allow responses to outbound connections back in.

iptables –-append INPUT \

–-match state –-state ESTABLISHED,RELATED –-jump ACCEPT

#Explicitly accept any connections from computers on

#192.168.10.0/24

iptables –-append INPUT –-source 192.168.10.0/24 –-jump ACCEPT

There’s good documentation about using the iptables command at the Linux netfilter website

         . There are also many high-quality tutorials and HOWTOs available via the netfilter website, in particular peruse the tutorials listed on the netfilter HOWTO page.

    

      

To add more than one SNMP server for alert traps, add the first SNMP server using the Management Console or the command line config tool. Secondary and any further SNMP servers are added manually using config.

Log in to the console server’s command line shell as root or an admin user. Refer back to the Management Console UI or user documentation for descriptions of each field.

To set the Manager Protocol field:

config --set config.system.snmp.protocol2=UDP or config --set config.system.snmp.protocol2=TCP

To set the Manager Address field:

config --set config.system.snmp.address2=w.x.y.z

.. replacing w.x.y.z with the IP address or DNS name.

To set the Manager Trap Port field:

config --set config.system.snmp.trapport2=162

.. replacing 162 with the TCP/UDP port number To set the Version field:

config --set config.system.snmp.version2=1 or config --set config.system.snmp.version2=2c or config --set config.system.snmp.version2=3

To set the Community field (SNMP version 1 and 2c only):

config --set config.system.snmp.community2=yourcommunityname

.. replacing yourcommunityname with the community name

To set the Engine ID field (SNMP version 3 only):

config --set config.system.snmp.engineid2=800000020109840301

.. replacing 800000020109840301 with the engine ID

146

724-746-5500 blackbox.com

Page 146
Image 146
Black Box 1101, Secure Device Servers To set the Manager Address field, Config --set config.system.snmp.address2=w.x.y.z