FDDI Management

Figure 4-10. SMT Connection Policy Window

FDDI Connection Rules

By default, all connections are allowed except the illegal M—>Mconnection; the following table summarizes the FDDI connection rules:

Table 4-1. FDDI Connection Rules

!

CAUTION

 

A

B

S

M

 

 

 

 

 

A

V, U (T)

V

V, U

V, DH

 

 

 

 

 

B

V

V, U (T)

V, U

V, DH

 

 

 

 

 

S

V, U

V, U

V

V

 

 

 

 

 

M

V, DH

V, DH

V

X

 

 

 

 

 

V— valid connection X — illegal connection

U — undesirable (but legal) connection

T — connection can lead to a twisted ring configuration

DH — when both A and B are connected to M ports, a dual-homing configuration results. See the following page for more information on dual homing.

Though technically legal under FDDI connection rules, the undesirable A—>S and B—>S connections will deprive your device of the redundancy protection built in to the FDDI dual-ring configuration. The SMT entity is notified each time an undesirable connection is made, even when that connection is allowed.