Using the 7C0x SmartSwitch Hub View
Figure 2-18. COM Port Configuration Window
You can use the COM Port Configuration window to set the following operating parameters:
COM Port Admin
Use this field to administratively enable or disable the COM port.
COM Port Function
Use this field to select the function for which you wish to use the COM port:
LM | Local Management: select this option if you wish to connect a |
| terminal to the selected COM port from which to run Local |
| Management. |
UPS | Select this option if you wish to connect an uninterruptable |
| power supply (UPS) to the selected COM Port. Note that if you |
| select this option, an additional option — UPS — will appear on |
| the COM Port menu; use the resulting window to configure |
| specific UPS settings. |
SLIP | Select this option to use the selected COM port as a SLIP |
| connection for |
| connection to a serial port on your network management |
| workstation. Note that when you configure the port as a SLIP |
| connection, you must select the desired baud rate in the Speed |
| Selection field described below. |
PPPSelect this option to use the selected COM port as a PPP connection for
Managing the Hub |