Command Descriptions
|
|
|
|
| GS ( A |
|
|
|
| VERSAJET MP3200 |
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Programming Reference | [Name] | Execute test print | ||||
|
|
|
|
| |||
|
|
|
|
| [Format] | ASCII | GS ( A pL pH n m |
|
|
|
|
|
| Hex | 1D 28 41 pL pH n m |
|
|
|
|
|
| Decimal | 29 40 65 pL pH n m |
|
|
|
|
| [Range] | (pL + (pH x 256)) = 2 (pL = 2, pH = 0) | |
|
|
|
|
| [Description] | Executes a specified test print. | |
|
|
|
|
|
| pL and pH specify the number of parameters following n to (pL + pH x 256) bytes. |
[Notes]
This command is effective only when processed at the beginning of the line in standard mode.
If this command is processed while a macro is being defined, the printer cancels macro definition and starts processing this command. At that time, the macro becomes undefined.
After processing this command, the printer performs a software reset. Executing this command puts the printer in the same status as when the power is turned on. Transmit commands or data after confirming the complete software reset.
In hexadecimal dump (m=1, 49) is specified, the printer prints a message. Transmit commands or data after the printing.
When processing printer status printing(m = 2, 50), rolling pattern printing (m = 3, 51), and automatic setting of paper layout (m = 64),
95 | Preliminary Rev. 02 |