VERSAJET MP3200

Command Descriptions

GS ( k RSS-14<Function 868>

Programming Reference

[Format]

ASCII

GS ( k pL pH cn fn n

 

Hex

1D 28 6B 03 00 38 44 n

 

Decimal

29

40 107 03 00 56 68 n

[Range]

(pL + pH x 256)

= 3 (pL = 3, pH = 0)

 

cn = 56

 

 

 

fn = 68

 

 

 

1 ”ҏҏn ”ҏ255

 

 

[Default]

n = 2

 

 

[Description]

Specifies the Height of separator of RSS-14 symbol.

[Notes]

‹Settings of this function affect the processing of Functions 881.

‹Settings of this function are effective until ESC @ is executed, the printer is reset, or the power is turned off.

‹Settings of this function affect the RSS-14 + Composite(2D) barcode.

[Model-dependent variations]

The setting unit is 1 dot. The width is set in units of 0.125 mm {1/203 inch}.