Command Descriptions
|
|
|
|
| GS ( k PDF417<Function 081> | ||
|
| VERSAJET MP3200 |
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Programming Reference | [Format] | ASCII | GS ( k pL pH cn fn m | |||
|
|
|
|
| |||
|
|
|
|
|
| Hex | 1D 28 6B 03 00 30 51 m |
|
|
|
|
|
| Decimal | 29 40 107 03 00 48 81 m |
|
|
|
|
| [Range] | (pL + pH x 256) = 3 (pL = 3, pH = 0) | |
|
|
|
|
|
| cn = 48, fn = 81 | |
|
|
|
|
|
| m = 48 |
|
|
|
|
|
| [Description] | Encodes and prints the PDF417 symbol data in the symbol save area. | |
|
|
|
|
| [Notes] |
|
|
If there is any error described below in the data of the symbol save area, it can not be printed.
There is no data (Function 080 is not processed).
If [(number of columns ×number of rows) < number of code word] when auto processing is specified for number of columns and number of rows.
Number of code word exceeds 928 in the data area.
This command does not affect printing in standard mode.
The following data are added automatically by the encode processing.
Start pattern and stop pattern.
There is no data (Function 080 is not processed).
The descriptor of symbol length (the first code word in the data area)
The error correction code word calculated by modulus 929.
Pad codeword.
124 | Preliminary Rev. 02 |