Command Descriptions
|
|
|
|
| GS ( k Datamatrix <Function 767> | ||
|
| VERSAJET MP3200 |
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Programming Reference | [Format] | ASCII | GS ( k pL pH cn fn n | |||
|
|
|
|
| |||
|
|
|
|
|
| Hex | 1D 28 6B 03 00 37 43 n |
|
|
|
|
|
| Decimal | 29 40 107 03 00 55 67 n |
|
|
|
|
| [Range] | (pL + pH x ҏ256) = 3 (pL = 3, pH = 0 ) | |
|
|
|
|
|
| cn = 55 |
|
|
|
|
|
|
| fn = 67 |
|
|
|
|
|
|
| 1 n 5 |
|
|
|
|
|
| [Default] | n = 1 |
|
|
|
|
|
| [Description] | Specifies the width of a module of Datamatrix symbol. |
[Notes]
Settings of this function affect the processing of Functions 781.
The setting unit differs, depending on the printer models.
Settings of this function are effective until ESC @ is executed, the printer is reset, or the power is turned off.
The setting unit is 1 dot. The width is set in units of 0.125 mm {1/203 inch}. |
140 | Preliminary Rev. 02 |