| GS ( k MaxiCode <Function 281> | ||
|
| VERSAJET MP3200 |
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Programming Reference | [Format] | ASCII | GS (k pL pH cn fn m | |||
|
|
|
|
| |||
|
|
|
|
|
| Hex | 1D 28 6B 03 00 32 51 m |
|
|
|
|
|
| Decimal | 29 40 107 03 00 50 81 m |
|
|
|
|
| [Range] | (pL + pH x ҏ256) = 3 (pL = 3, pH = 0 ) | |
|
|
|
|
|
| cn = 50 |
|
|
|
|
|
|
| fn = 81 |
|
|
|
|
|
|
| m = 48 |
|
|
|
|
|
| [Default] | None |
|
|
|
|
|
| [Description] | Encodes and prints the MaxiCode symbol data in the symbol save area. | |
|
|
|
|
| [Notes] |
|
|
f there is any error described below in the data of the symbol save area, it cannot be printed.
There is no data (Function 180 is not processed).
Follow to the <Function 280> [Data format], If any improper data is included, it will result as a command error .
ESC T is not effective for QR Code, Datamatrix, or MaxiCode.
Barcode Size :Width approximately 28mm(1.01inch); Height approximately 25mm(1inch).
This command is effective only in Page mode.