VERSAJET MP3200

Programming Reference

Command Descriptions

For UPC-A (m = 0, 65) process

‹Modular check character is processed as follows:

„Automatically added when processing data is 11 byte.

„The 12th byte data is processed as a modular check character when processing data is 12 byte. In this case, modular check character is not checked.

‹Left guard bar/center bar/right guard bar are added automatically.

For UPC-E (m = 0, 66) process

‹The first data (d1) is processed as number system character (NSC) so 0 must be specified.

‹If n is out of the specified range or if n is an odd number when ITF bar code system (m =

70)is selected, this command is canceled and the following data is processed as normal data.

‹Modular check character is processed as follows:

„ Automatically added when processing data is 11 byte.

„ The 12th byte data is processed as a modular check character when processing data is 12 byte. In this case, modular check character is not checked.

„ Modular check characters are data to decide bar code pattern, they are not included printing data.

165

Preliminary Rev. 02

Page 171
Image 171