VERSAJET MP3200

Programming Reference

Command Descriptions

For JAN8/EAN8 (m = 3, 68) process

‹Modular check character is processed as follows:

„Automatically added when processing data is 7 byte.

„The 8th byte data is processed as a modular check character when processing data is 8 byte. In this case, modular check character is not checked.

‹Left guard bar/center bar/right guard bar are added automatically.

For CODE39 (m = 4, 69) process

‹The printer processes the start code (ASCII = */ Hex = 2Ah/Decimal = 42) as follows:

„When the first bar code (d1) is “*”, the printer processes the data as a first character.

„If the first bar code (d1) is not “*”, the printer adds a start character (*) automatically.

‹The printer processes the start code (ASCII = */ Hex = 2Ah/Decimal = 42) as follows:

„When the last bar code (dk or dn) is “*”, the printer processes the data as a last character.

„If the last bar code (dk or dn) is not “*”, the printer adds a last character (*) automatically.

„When “*” is processed during bar code data processing, the printer processes “*” as a stop character. The printer prints data preceding “*” and finishes command processing. Therefore, data following “*” are processed as normal data.

‹Check digits are not calculated and added.

167

Preliminary Rev. 02

Page 173
Image 173
Cino MP3200 manual For JAN8/EAN8 m = 3, 68 process, For CODE39 m = 4, 69 process