VERSAJET MP3200
Programming Reference
Command Descriptions
For JAN8/EAN8 (m = 3, 68) process
Modular check character is processed as follows:
Automatically added when processing data is 7 byte.
The 8th byte data is processed as a modular check character when processing data is 8 byte. In this case, modular check character is not checked.
Left guard bar/center bar/right guard bar are added automatically.
For CODE39 (m = 4, 69) process
The printer processes the start code (ASCII = */ Hex = 2Ah/Decimal = 42) as follows:
When the first bar code (d1) is “*”, the printer processes the data as a first character.
If the first bar code (d1) is not “*”, the printer adds a start character (*) automatically.
The printer processes the start code (ASCII = */ Hex = 2Ah/Decimal = 42) as follows:
When the last bar code (dk or dn) is “*”, the printer processes the data as a last character.
If the last bar code (dk or dn) is not “*”, the printer adds a last character (*) automatically.
When “*” is processed during bar code data processing, the printer processes “*” as a stop character. The printer prints data preceding “*” and finishes command processing. Therefore, data following “*” are processed as normal data.
Check digits are not calculated and added.
167 | Preliminary Rev. 02 |