GS ( k Datamatrix <Function 781>

 

 

VERSAJET MP3200

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Programming Reference

[Format]

ASCII

GS ( k pL pH cn fn m

 

 

 

 

 

 

 

 

 

 

 

Hex

1D 28 6B 03 00 37 51 m

 

 

 

 

 

 

Decimal

29 40 107 03 00 55 81 m

 

 

 

 

 

[Range]

(pL + pH x 256) = 3 (pL = 3, pH = 0)

 

 

 

 

 

 

cn = 55

 

 

 

 

 

 

 

fn = 81

 

 

 

 

 

 

 

m = 48

 

 

 

 

 

 

[Description]

Encodes and prints the Datamatrix symbol data in the symbol save area.

[Notes]

‹If there is any error described below in the data of the symbol save area, it can not be printed.

„There is no data (Function 780 is not processed).

„If [(number of columns ×number of rows) < number of code word] when auto processing is specified for number of columns and number of rows.

„Number of code word exceeds 928 in the data area.

„This command does not affect printing in standard mode.

‹The following data are added automatically by the encode processing.

„Start pattern and stop pattern

„Indicator code word of left and right

„The descriptor of symbol length (the first code word in the data area)

„The error correction code word calculated by modulus 929

„Pad codeword